Relay useYou are the location - "Home -"Relay use

Practice has proved, relay about more than 70% of the fault occurred in the contact, It shows the correct selection and use 

of the relay contact is very important

 

1. Ac/Dc electromagnetic relay selection

Almost all of the AC relay from have the humming because of armature of chatter . When the relay coil voltage (or current) did 

not meet the prescribed operation value, armature vibration can cause contact dithering, if contact on surge current load, the 

flutter cause arc may make contact melting or welding.

 

2. The selection of voltage relay operation

Relay work, coil should be applied rated working voltage (current), rather than with the pull in voltage (current), so that the relay 

coil voltage (or current) in the power supply voltage (or current) wave or relay use environment in mechanical vibration impact or 

environmental temperature, it is a reliable work insurance allowance. Pull in voltage (or current) is only factory constraint relay 

sensitivity and the judgment of the assessment parameters. The relay release voltage does not necessarily the bigger the better.

 Relay release, if the coil circuit of the leakage current is too big, relay will not reliable release.

 

3. Relay load ability choose and failure analysis

Relay in use, are the following several kinds of load

A. incandescent lamp load

Because incandescent lamp inside of tungsten wire cold resistance is very small, so on instantaneous surge current up to steady 

current 15 times. So big surge current can make the contact rapidly corrosion, and even cause welding failure.

B. capacitive load

Charging current of the Capacitive circuit, short circuit discharge current when starting , Charge or short circuit discharge, contact

 may be because of the charging current is too big and have serious ablation or welding failure. When use, such as can according 

to the size of the electric capacity, appropriate cascading current-limiting resistance can eliminate the hazards.

C. motor load

During the motor dormant,the input impedance is very small, so just start, surge current very large. Due to the motor load size is 

different, it may start time is very short, may also be very long, so start surge current also continues to the same long time. In 

addition with relay contact as a motor on-off switch, shut off the time relay must bear motor winding high induction reverse voltage surge generated arc, so contact between

 group insulation resistance to electric level and the ability to bear a load must have sufficient margin.

D. inductor. Spiral coil. Contactor coil. Choke. Electromagnet coil load these load belongs to the strong perceptual load. Use relay

 contact such as load intermittent automatic switch, when the relay shut off, the coil of the energy storage must be through the disconnect 

between the contact arc release, consumption, often leads to contact ablation, welding or insulation parts failure. In just on the load, 

due to low input impedance, as the motor load, also can produce strong surge current.

F. Dc load

Dc load than Ac load more difficult to break. Ac voltage automatic over zero hour automatic arcing. Dc voltage produce arc and continuous 

don't extinguish until arc elongated (contact gap increases) and not self sustaining so far. Arc energy can make the contact have serious 

corrosion, metal transfer, the splash damage, etc.

G. Ac load

Relay contact Ac rated value is only applicable in the frequency of the provisions . Different frequency condition, relay switching ability is

 different. In switching out-of-step single-phase ac load, will exist phase difference, so should choose contact rated voltage for load voltage 2 times, rated current for load current

 4 times products.

H. low level load mechanical and electrical current load

Under the action of load, because of the pollution of the environment, production process of pollution and adsorption in contact surface 

organic matter will further sudden close, due to the load level is too small and not breakdown organic or oxide film, and cause contact 

resistance increase or unstable, even cause open circuit failure.